Room air conditioner manual. CARRIER ROOM AIR CONDITIONER USER MANUAL Pdf Download. 2019-03-23

Room air conditioner manual Rating: 6,4/10 1941 reviews

LG ROOM AIR CONDITIONER INSTALLATION MANUAL Pdf Download.

room air conditioner manual

So all the pictures in this manual are for explan- ation purpose only. Drill the piping hole at either Indoor Outdoor the right or the left with the hole slightly slanted to the outdoor side. Check that all tubing and wiring are properly connected. Interior pulido sin rayas 2. Cooling Heating To effectively cool the whole room, please To effectively heat the bottom of the room please set the louver downwards. Reliez-les ensemble avec du ruban adhésif pour qu'il ne reste aucun espace vide entre eux. Enlevez le couvercle du compartiment des piles en tirant de celui-ci dans la direction indiquée par la flèche.

Next

LG Air Conditioner Units: Stay Cool & Comfortable

room air conditioner manual

Ensure that the hooks are properly seated on the Drain hose installation plate by moving it left and right. Superposez l'isolant thermique du tuyau de raccordement et celui du tuyau de l'unité intérieure. Features Air Inlet Plasma Filter Air Filter Front Panel. Horizontal air flow grille inside 7. Haga coincidir los dos ganchos de la Cable de conexión parte superior posterior de la unidad interior con la parte superior de la placa de instalación.

Next

CARRIER ROOM AIR CONDITIONER USER MANUAL Pdf Download.

room air conditioner manual

Solape el aislamiento térmico del conducto de conexión y el material de aislamiento térmico del conducto de la unidad interior. Copper Slanted Uneven Rough 2. This is a normal condition when the air conditioner has not been used for a long time or during first use of the unit. For example: If the unit intially started operates under cool or fan mode, the other units can operate under any mode except heat. Vertical air flow louver inside 7. Disconnect the power and contact the nearest customer service center.

Next

LG ROOM AIR CONDITIONER INSTALLATION MANUAL Pdf Download.

room air conditioner manual

Le courant de fonctionnement augmente. Réussissez le travail d'évasement à l'aide de la procédure suivante. Designed for the way you live, they're available in a wide range of styles -- so you can create a space that's cool, comfortable and stylish, such as: Portable: Take cool breezes with you from room to room, house to house, or from home to work. Installation de l'unité intérieure Accrochez l'unité intérieure dans la partie supérieure de la plaque d'installation. Utilice el equipo de conductos opcional o los conductos comprados. Installation plate Sleeve Bushing-Sleeve Putty Gum Type Sealer Bend the pipe as closely on the wall as possible, but be careful that it doesn't break.

Next

LG Air Conditioner Units: Stay Cool & Comfortable

room air conditioner manual

Este sistema acondicionador de aire cumple estrictamente las normas de funcionamiento y seguridad. L'efficacité de refroidissement ou de chauffage diminue. Realice correctamente el trabajo de abocinamiento mediante el siguiente procedimiento. Now Pump Down procedure is completed, and all refrigerant is collected into the outdoor unit. Clean the indoor unit and air filter. Water may enter the unit and degrade An oxygen shortage the insulation. Plaque d'installation Manchon de raccordement Douille de raccordement Mastic produit d'étanchéité ressemblant à de la gomme Tordre la pipe aussi près du mur que possible en faisant attention de ne pas la briser.

Next

LG ROOM AIR CONDITIONER INSTALLATION MANUAL Pdf Download.

room air conditioner manual

Carry out correct flaring work in the following procedure. Then pull down the air-in grill. The air conditioner is now ready to test run. Horizontal air flow grille outside 6. Se incrementa el consumo eléctrico. This symbol alerts you to hazards that may cause harm to the air conditioner.

Next

LG Air Conditioner Units: Stay Cool & Comfortable

room air conditioner manual

Asegúrese de que el agua fluye a través de Área de conexión de la manguera de drenaje la manguera de drenaje de la unidad interior sin ninguna fuga y que sale por la salida de drenaje. For the unit is a descensional ventilated one, please push the filter up slightly to let the position retainer escape away from the flange fixed holes, and take off the filter according to the arrow direction shows in the. Clean the air cleaning filter with water or vacuum cleaner, then dry it in cool place. Vérifiez que tous les tuyaux et les câbles ont été correctement connectés. Rear air intake grille 3. Consult with the sales agency or manufacturer for details. The seriousness is classified by the following indications.

Next

LG ROOM AIR CONDITIONER INSTALLATION MANUAL Pdf Download.

room air conditioner manual

If the unit intially started operates under heat mode, the other units can operate under heat mode only. Take off the especial function filter Hold the tabs of the frame, and remove the claws in 4 places. Pour a glass of water on the evaporator. Trap 24 Room Air Conditioner. This air conditioning system meets strict safety and operating standards. Overlap the connection pipe heat insulation and the indoor unit pipe heat insulation material. Retire la tapa del puerto de servicio de la válvula de 3 vías.

Next

LG ROOM AIR CONDITIONER INSTALLATION MANUAL Pdf Download.

room air conditioner manual

Compare el trabajo de abocinamiento con la Liso todo alrededor figura. Cooling or heating efficiency drops. This completes air purging with a vacuum pump. Air flow louver at air outlet 2. Select a place where the warm air and noise from the air conditioner do not disturb neighbors.

Next

LG Air Conditioner Units: Stay Cool & Comfortable

room air conditioner manual

Fije el cable a la placa de control con el soporte Sobre los Panel de conductos abrazadera. Take the weight of the air conditioner into account and select a place where noise and vibration are minimum. Form a trap to prevent water entering the room. Comparez votre travail d'évasement avec la Polir tout rond figure ci-dessous. Drain hose Indoor unit drain hose Vinyl tape narrow Adhesive 16 Room Air Conditioner. Operating temperature Mode Cooling operation Heating operation Drying operation Temperature Room temperature 17 C~32 62 F~90 F~90 F C 3 F~86 F 0 C~50 C Outdoor temperature. Versez un verre d'eau dans l'évaporateur.

Next